Industrial Manufacturer in Pune, Maharashtra · Serving All India

Dust-Free Finishes · Pressurised Booths

Air Handling Unit
Manufacturer in Pune

Engineered air make-up units (AMUs), fresh air handling units, and downdraft floor ventilation systems for paint shops, booth pressurization, and facility-level air management. Keep dust out, maintain airflow velocity, and ensure operator safety.

Free airflow audit Proposal within 24 hours HVAC integration ready

Air Quality Guaranteed

Air Handling Unit Manufacturer in Pune
Get Instant Quote on WhatsApp

What We Build

Perfect Finishes
Start With
Perfect Air

You can have the best paint booth and the most expensive powder, but if the air entering your booth is dusty or humid, your finish will fail. Air is the invisible ingredient in every coating process.

Air Handling Unit Manufacturer in Pune

Our Air Handling Units (AHUs) and Air Make-Up Units (AMUs) are engineered to do three things perfectly: filter out dust, control temperature/humidity, and maintain the exact static pressure your booth requires.

Whether you need 100% fresh air to replace exhausted solvent-laden air, or a recirculating system for energy efficiency, we design the fan curves, filter banks, and ducting to match your specific paint shop. Every AHU is wired, programmed, and factory-tested before it leaves our Pune facility.

Stable Airflow

VFD-driven fans maintain exact CFM regardless of filter loading or duct static pressure.

Dust Exclusion

Multi-stage filtration (Pre-filter + Bag + HEPA) ensures only clean air enters the booth.

Energy Recovery

Optional heat wheels or plate exchangers recover up to 60% of exhaust heat.

Our Product Range

Air Management Systems
We Manufacture

From standalone fresh air units to complete facility-wide pressurization and extraction networks.

01

Air Make-Up Units (AMU)

Supplies tempered fresh air to replace the air exhausted by paint booths and ovens. Prevents negative pressure in the factory and maintains a comfortable working environment.

  • 100% Fresh Air
  • Tempered Supply
  • Balances Exhaust
02

Fresh Air Handling Units

Draws outside ambient air, filters it, and conditions it (heating or cooling) before supplying it to the paint booth or clean room.

  • Outside Air
  • Heating / Cooling
  • Humidity Control
03

Downdraft Floor Ventilation

Full-width exhaust floor grating that pulls air evenly downward. Ensures overspray and solvent vapours are pulled away from the operator's breathing zone.

  • Floor Grates
  • Even Extraction
  • Operator Safety
04

Paint Booth Pressurization

Precisely balances supply and exhaust fans to maintain positive pressure in the booth. Stops dust from the surrounding factory from entering the paint zone.

  • Positive Pressure
  • Dust Exclusion
  • VFD Balancing
05

Dust & Fume Extraction

High-static exhaust fans and ducting networks designed to pull solvent fumes, paint mist, and welding smoke safely out of the facility to the exhaust stack.

  • High Static Fans
  • Ducting Design
  • Safe Discharge
Most Popular
06

Turnkey HVAC Integration

Complete air management for the entire facility combining supply, exhaust, heating, cooling, and filtration into one PLC-controlled network.

  • Facility Wide
  • PLC Controlled
  • Energy Efficient

Key Specifications

Technical
Data

Standard configuration parameters all customizable to your paint shop layout and airflow requirements.

Email for Datasheet
Airflow Capacity (CFM) 2,000 – 40,000 CFM (custom)
Filtration Stages Pre-filter (G4) + Bag (F7/F9) + HEPA (H13)
Heating Options Gas / Electric / Steam / Hot Water Coil
Cooling Options Chilled Water Coil / DX Coil
Fan Type Plug Fan / DIDW Centrifugal Fan
Drive System VFD (Variable Frequency Drive)
Panel Construction Double-skinned, 40mm PUF / Rockwool insulated
Control System PLC with HMI or Standalone Controller
Custom ducting design included Factory tested before dispatch

The Sairaj Advantage

Why Choose Our
Air Handling Units

100% In-House

Panel fabrication, fan assembly, coil installation, and panel wiring all done by our team.

Energy Efficiency

VFDs, PUF insulated panels, and optional heat recovery wheels cut your HVAC running costs.

Precision Balancing

We calculate and field-balance airflow to ensure your booth maintains 0.5 m/s face velocity.

Pan-India Support

AMC, filter media supply, and emergency breakdown support across India.

How We Deliver

Our 5-Stage
Delivery Process

01

Consult & Survey

Site survey, booth exhaust calculation, static pressure requirements, and duct routing.

02

Design & Approve

Fan curve selection, coil sizing, filter selection, and 3D ducting layout.

03

In-House Build

PUF panel fabrication, fan mounting, coil installation, and control panel wiring.

04

Site Installation

Rigging the AHU, connecting ducting, wiring the VFDs, and sealing joints.

05

Test & Handover

Air balancing (CFM measurement), static pressure check, operator training, and sign-off.

Common Questions

AHU
FAQ

Still have a question? Our air systems engineers reply within 24 hours.

What is the difference between an AHU and an AMU?
An AHU (Air Handling Unit) is a general term for a machine that conditions and circulates air (it can mix return air and fresh air). An AMU (Air Make-Up Unit) specifically supplies 100% outside fresh air to replace the air that has been exhausted from the building by paint booths or ovens. In a paint shop, you usually need both: AMUs to replace exhausted air, and AHUs for heating/cooling the workspace.
Why is positive pressure important in a paint booth?
If a paint booth is at negative pressure, the exhaust fan will suck dust from the surrounding factory floor directly into the paint zone, ruining your finish. By slightly over-supplying air (using a supply fan that is slightly stronger than the exhaust fan), we maintain positive pressure. This ensures that when the operator opens the door, air rushes out, keeping dust out.
What filtration do I need for my paint booth?
For standard industrial paint booths, a 3-stage filtration is recommended: Pre-filter (G4) to catch large dust, Bag filter (F7 or F9) to catch fine dust, and a final ceiling filter (EU5 or HEPA H13) right at the booth entrance. If you are painting automotive Class-A surfaces, HEPA H13 is mandatory.
How do you handle solvent fumes and VOC exhaust?
We design high-static exhaust fans and duct networks to pull fumes from the booth. Depending on your local Pollution Control Board norms, we can integrate activated carbon filters or thermal oxidizers (RTO) before the exhaust stack to neutralize VOCs. The stack height is also engineered to disperse emissions safely.
Can you provide ducting and installation?
Yes. We fabricate GI or SS ducting in-house to match the AHU capacity and site layout. Our team handles the entire installation mounting the AHU, running the ducting, installing dampers, and connecting the VFDs. We also perform air balancing at the site to ensure the CFM targets are met.

Have a specific air quality requirement?

Share your booth layout and exhaust needs our engineers will design the right AHU.

Ready to Order

Get Your AHU Engineered
& Delivered.

Free airflow audit · Detailed proposal in 24 hours · 15-year design lifespan.

Call WhatsApp Get Quote